International Research Journal of Biological Sciences ___________________________________ ISSN 2278-3202Vol. 4(9), 48-53, September (2015) Int. Res. J. Biological Sci. International Science Congress Association 48 Assessment of Bacteria and Fungi in air from College of Applied Medical Sciences (Male) at AD-Dawadmi, Saudi Arabia Gouse Basha Sheik, Ali Ismail Ali Abd Al Rheam, Zafer Saad Al Shehri, Omar Bin MuathAl Otaibi, College of Applied Medical Sciences, Shaqra University, Al-Dawadmi, KINGDOM OF SAUDI ARABIA Available online at: www.isca.in, www.isca.me Received 8th August 2015, revised 14th August 2015, accepted 8th September 2015 Abstract This study was conducted to learn the microbial diversity in our college environment so that we can we can develop a database of the microbial load and to have a preliminary idea of the environmental status. A total of 125 samples were collected in duplicate by open plate method from 5 different sites (Microbiology Laboratory, Classrooms, Toilets, Lift and Office rooms) at College of Applied Medical Sciences, Dawadmi was experimentally investigated during Months of October 2014 to February 2015. The number of Bacteria and fungi present in our college environment were studied by exposing Nutrient agar and Sabouraud Dextrose Agar plates for 30 minutes at different sites. The bacteria isolated were; Staphylococcus aureus, Coagulase –ve Staphylococcus, Micrococcus species and Bacillus species. The moulds isolated were Aspergillus fumigatus, Aspergillus niger, Alternaria species and Penicillium species. The yeast belonging to Rhodotorula species was also isolated. The data collected in this study can used for further research. Although microorganisms are present in our college, the amount is within the range (61 - 460 CFU/m) which indicates a low level of contamination according to the guidelines by World Health Organization. Keywords: Bacteria, fungi, moulds, yeasts, faculty of applied medical science, Shaqra University. Introduction Most of the people live indoors: in houses, offices, schools, colleges, hospitals etc., where they are exposed to many envi-ronmental conditions that effect their health.Microorganisms are normally present in both indoor and outdoor environments. The quantity of microorganisms in a particular area depends upon the presence of water and other nutrient sources in that particular environment where they can develop extensively. Usually microorganisms enter into buildings through the doors, windows, air conditioners and also by people entering from outside. The type of species and amount of organisms present depends on the viscosity, temperature, lighting and food available in that particular environment. Among the microorganisms present in the indoor environment, some species of microorganisms if present beyond the limit can cause serious health problems. So the isolation, identification and measurement of different types of microorganisms especially in indoor environment has become a very hot topic at present and it has attracted everyone’s attention in this field2-4. Among the indoor microorganisms, some may be pathogenic and could secrete toxic metabolites which can cause allergy and even serious diseases. The amount of fungi after entering from the outdoor environment increases when they have favorable conditions in the indoor environment and can cause health problems not only to those having immunodeficiency but also to healthy people. The main factors helping in growth of and multiplication of both pathogenic and non-pathogenic fungi are temperature, humidity and the hygienic conditions present in the different areas of the building. Actually the favorable conditions that fungus needs is moisture when there is some water leakage from the roof and plumbing, more humidity or dampness. Microorganisms are also present in dust present on surfaces in the rooms which come from outside due to walking, vehicles or from wind.Since a number of students are studying in our college attending both theory and practical sessions they are exposed to a number of pathogenic fungi and bacteria which can affect their health if proper care is not taken. Various environmental conditions such as UV light, temperature, humidity and dryness, play a major role in controlling the growth of microorganisms from growing in unfavourable environments. But still the microbes manage to reach new hosts through the air for its survival. Among dust particles present in the indoor environment, some bacteria especially which belong to Gram-positive, fungus which have spores and some viruses can survive for several months. Because of the lack of air circulation and increase in number of air conditions inside buildings now days the chance of airborne infections has grown up8,9. The studies on indoor air quality in our college have not yet been reported so far. The aims of this study are the assessment of air microflora (especially bacteria, moulds and yeasts) and determination of the factors responsible for their presence in the rooms. Microbial assessments in air are not an easy task. The load of microorganisms in the air can be measured by using air sampler method or by using simple settle plate method and by calculating the colony forming units per cubic meter of air (CFU/m10. Research Journal of Biological Sciences ___________________________________________________________ ISSN 2278-3202 Vol. 4(9), 48-53, September (2015) Int. Res. J. Biological Sci. International Science Congress Association 49 Material and Methods Sample Collections: The number and type of microorganism’s present in indoor air was investigated in College of Applied Medical Sciences for Males at Ad-Dawadmi, Kingdom of Saudi Arabia in selected rooms. The study was conducted during the months of October 2015 to February 2015. A total of 125 samples were collected in duplicate from different sites of the college such as microbiology laboratory, class rooms, toilets, lift and office rooms. Isolation and identification: The number of Bacteria and fungi present in our college environment were studied by exposing Nutrient agar and Sabouraud Dextrose Agar plates for 30 minutes during the working hours 10 - 12 pm at different sites.. After the exposure and collection, the plates were taken to the Microbiology laboratory and incubated at 37º C for 24 hours for isolation of bacteria and incubated at 28ºC for 5-7 days for isolation of fungi. The total number of bacteria, yeast and moulds in the air samples collected from different sites collected was determined. The total number of colony forming unit (CFU/m) was calculated. Then it is converted to organisms per cubic meter air using the standard equation given below  \n \n \r\n\n \r\n \r\r\r\r\r\r \r \r\n\r   Identification of bacteria and fungi was done using the standard procedures11. The bacterial cultures were identified by usingmicroscopic (using staining techniques), macroscopic characteristics and biochemical reactions. The fungal cultures were identified on the basis of microscopic (using Lactophenol cotton blue staining and wet mounting techniques) and macroscopic characteristics12. Results and Discussion In this study, the microbial concentration of indoor air differs from sampling area to area as shown in table-1 and figure-1.The results show that the average number of highest bacterial concentration of air has been recorded in laboratories (320 CFU/m and average of the lowest bacterial concentration of air has been recorded in office rooms (61 CFU/m3). The average number of highest fungal concentration of air has been recorded in laboratories (460 CFU/m3) and the average of lowest fungal concentration of air has been recorded in office rooms (140 CFU/m). The Total of fungal concentration of air was greater than that of the bacterial concentration in all the collection sites. Table-1 Average number of bacterial and fungal count (CFU/m) in air samples Sampling site Bacteria (CFU/m3 ) Fungi (CFU/m3 ) Laboratories 320 460 Classrooms 290 340 Toilets 240 280 Lift 180 360 Office rooms 61 140 Total (CFU/m ) 1091 1580 Figure-1 Comparison of average number of bacterial and fungal counts (CFU/m) 3202902401806146034028036014050100150200250300350400450500LaboratoriesClassroomsToiletsLiftOffice roomsNumber of CFU m3Collection sites Bacteria Fungi Research Journal of Biological Sciences _ _____________________ Vol. 4(9), 48-53, September (2015) International Science Congress Association A total of 69 bacterial isolates belonging to 4 genera identified in this study as shown in figure- 2. Among them 3 isolates belong to Gram positive cocci ( Staphylococcus aureus, Coagulase negative Staphylococcus and Micrococcus species One isolate was spore forming Gram positive rod belonging to Bacillus species. Among them Staphylococcus species dominant, since the percentage frequency of aureus is 38% and Coagulase negative Staphylococcus But Bacillus species and Micrococcus species are less frequent with 17% and 19% respectiv ely as shown in the figure did not isolate any gram negative bacteria in this study. Micrococcus species was not found in office rooms. species was not found in both office rooms and lift. A total of 97 fungal isolates belonging to 5 genera in this study as shown in figure- 3. Among them 4 isolates were filamentous fungi namely Aspergillus fumigatus, Aspergillus niger, Alternaria species and Penicillium species. was yeast belonging to Rhodotorula species. Aspergillus species, Alternaria species and Penicillium species were also reported by other workers13,14. Aspergillus fumigatus is the most dominant species isolated in this study with 40% frequency. Followed by Aspergillus niger , Alternaria species with 24% and 20% respectively. But Penicillium species Rhodotorula species are less frequent with 10% and 6% respectively as shown in the figure-5. Alternaria species whereas. Penicillium species and Rhodotorula species found in both lift and office rooms. Since air does not contain any nutrients and has low moisture content it is not conducive to the growth and survival of micro organisms but it can act as important medium for carrying and spreading of biological agents. The order of preva microflora from highest to lowest in microbiology laboratory, classrooms, toilets, lift and office rooms. The results from this study showed that the microbiology laboratory, classrooms and toilets have more percentage of contamination with indoor bacteria and fungi comparing to lift and office rooms. The high Frequency of different bacterial species isolated from different sites _____________________ _________________________ ____________ International Science Congress Association A total of 69 bacterial isolates belonging to 4 genera are 2. Among them 3 Staphylococcus aureus, Staphylococcus and Micrococcus species ). One isolate was spore forming Gram positive rod belonging to Staphylococcus species was dominant, since the percentage frequency of Staphylococcus Staphylococcus is 26%. species are less frequent ely as shown in the figure -4. We did not isolate any gram negative bacteria in this study. was not found in office rooms. Bacillus was not found in both office rooms and lift. A total of 97 fungal isolates belonging to 5 genera are identified 3. Among them 4 isolates were Aspergillus fumigatus, Aspergillus niger, Alternaria species and Penicillium species. One isolate Rhodotorula species. Presence of Aspergillus species, Alternaria species and Penicillium species Aspergillus fumigatus is the most dominant species isolated in this study with 40% , Alternaria species Penicillium species and are less frequent with 10% and 6% Alternaria species in lift Rhodotorula species was not Since air does not contain any nutrients and has low moisture content it is not conducive to the growth and survival of micro - organisms but it can act as important medium for carrying and The order of preva lence of air microflora from highest to lowest in microbiology laboratory, The results from this study showed that the microbiology laboratory, classrooms and toilets have more percentage of contamination with indoor bacteria and fungi comparing to lift and office rooms. The high rates in Microbiology laboratory is due to handlin microbiological specimens during practical hour’s inspite of using disinfection procedures. The reasons for high percentage of bacteria and fungi the toilets are due to improper and low degree of hygiene and cleanness because of minimal usage of disin fection procedures against airborne microorganisms which has given rise to bio- contaminants. Lowest number of airborne bacteria and fungi were recorded in office rooms because of the regular cleaning of the floors properly with disinfectants and using room fresheners frequently. The number of bacteria and fungi is more in classrooms than that of the office rooms because of more number of students attending lecture classes during working hours but there are only few number of persons working in office rooms. The reason for more number of bacterial colonies in lift may be due to the dust coming from outside from the persons using the lift continuously during the working hours. The number of bacterial colonies in air samples from toilets is greater than the li ft samples while the number of bacterial colonies in dust samples from toilets is less than the lift samples. The reason is unknown. In order to safeguard the health of students, staff and workers proper control measures has to be env ironmental factors which favor the growth and proliferation of different bacteria and fungi in indoor environment of the college building15. More concentration should be given on maintenance of air conditioners because they can transmit biological agents s uch as allergen, mycotoxin, volatile organic compounds etc., into the air which can cause health problems. In order to develop the quality of indoor air in the college building first overcrowding has to be avoided and good ventilation systems has to be de signed more moisture due to cracks in the wall, fungal spores can easily dispersed through the droplets and it can grow and proliferate extensively. Since our college building is new there are no cracks and moisture present in the wa chance of extensive growth of fungi. Figure-2 Frequency of different bacterial species isolated from different sites ____________ ISSN 2278-3202 Int. Res. J. Biological Sci. 50 rates in Microbiology laboratory is due to handlin g of microbiological specimens during practical hour’s inspite of using disinfection procedures. The reasons for high percentage of bacteria and fungi the toilets are due to improper and low degree of hygiene and cleanness because of minimal usage of fection procedures against airborne microorganisms which contaminants. Lowest number of airborne bacteria and fungi were recorded in office rooms because of the regular cleaning of the floors properly with disinfectants and fresheners frequently. The number of bacteria and fungi is more in classrooms than that of the office rooms because of more number of students attending lecture classes during working hours but there are only few number of persons The reason for more number of bacterial colonies in lift may be due to the dust coming from outside from the persons using the lift continuously during the The number of bacterial colonies in air samples ft samples while the number of bacterial colonies in dust samples from toilets is less than the lift health of students, staff and workers proper control measures has to be taken to inhibit the ironmental factors which favor the growth and proliferation of different bacteria and fungi in indoor environment of the More concentration should be given on maintenance of air conditioners because they can transmit uch as allergen, mycotoxin, volatile organic compounds etc., into the air which can cause health problems. quality of indoor air in the college building first overcrowding has to be avoided and good signed 16. If the building has more moisture due to cracks in the wall, fungal spores can easily dispersed through the droplets and it can grow and proliferate extensively. Since our college building is new there are no cracks and moisture present in the wa lls, so there is a little chance of extensive growth of fungi. Research Journal of Biological Sciences ___________________________________________________________ ISSN 2278-3202 Vol. 4(9), 48-53, September (2015) Int. Res. J. Biological Sci. International Science Congress Association 51 Figure-3 Frequency of different fungal species isolated from different sitesFigure-4 Percentage frequency of bacterial isolatesIn our study, Staphylococcus species, Bacillus species and Micrococcus species were among dominantly isolated bacteria. Since some of the Micrococcus species and Staphylococcus species belong to normal flora of the human skin, it is likely that these microorganisms may be originated from the skin flora of the staff and students of our college. However, Staphylococcus aureus may cause disease through invasion and toxin production such as abscess, pneumonia, diarrhoea and the most feared toxic shock syndrome. Bacillus species can survive in the air for longer period of time since it produces spores which are resistant against severe environmental conditions. Many fungal spores have the ability to cause allergies as well as other respiratory diseases and hypersensitivity reactions not only in immunosuppressed patients but also in healthy individuals. The fungi belonging to Aspergillus species is found dominant in our study. Aspergillus species can cause invasive Aspergillosis and produce mycotoxins which are known to be carcinogens. Other fungal spores also have the ability to cause allergies as well as other respiratory diseases and hypersensitivity reactions not only in immune suppressed patients but also in healthy individuals17. Hence, more attention should be given to safeguard indoor environments otherwise the growth of pathogenic microorganisms can cause toxigenic health hazards. 1112554400101214Microbiology labClassroomsToiletsLiftOffice roomsNumber of fungal isolatesCollection Sites Aspergillus fumigatus Aspergillus niger Alternaria species Penicillium species 38%26%17%19%0%5%10%15%20%25%30%35%40%Staphylococcus aureusCoagulase –ve Staphylococcus Bacillus speciesMicrococcus species Research Journal of Biological Sciences ___________________________________________________________ ISSN 2278-3202 Vol. 4(9), 48-53, September (2015) Int. Res. J. Biological Sci. International Science Congress Association 52 Figure-5 Percentage frequency of fungal isolates Conclusion Although microorganisms are present in our college, the amount is within the range (61 - 460 CFU/m) which indicates a low level of contamination according to the guidelines established by World Health Organisation18. In order to improve quality of indoor air more care should be taken to avoid overcrowding and to have good ventilation. Air conditioner should be maintained regularly. Laboratories and toilets should be cleaning and disinfected daily. Acknowledgements The authors are grateful to the Dean, College of Applied Medical Sciences (Boys) at Dawadmi and also to the Head of the Department, Clinical Laboratory Sciences for permitting us to conduct the research, for laboratory facilities and also encouraging us to do research activities in our college. References 1.Slawomira M., Duma\na and Marzenna R. Dudzinska., Microbiological Indoor Air Quality in Polish Schools, Annual set the environmental protection, 15, 231-244 (2013)2.Huttunen K., Rintala H., Hirvonen M.R., Vepsalainen A., Hyvarinen A. and Meklin T., Indoor air particles and bioaerosols before and after renovation of moisturedamaged buildings, Environmental Research, 107, 291–298 (2008)3.Kim K.Y. and Kim C.N., Airbornemicrobiological characteristics in public buildings of Korea, Building and Environment, 42, 2188–2196 (2007) 4.Stanley N.J., Kuehn T.H., Kim S.W., Raynor P.C., Anantharaman S. and Ramakrishnan M.A., Background culturable bacteria aerosol in two large public buildings using HVAC filters as long term, passive, high-volume air samplers, Journal of Environmental Monitoring, 10,474–481 (2008)5.Stryjakowska Sekulska M., Piotraszewska Pajak A., Szyszka A., Nowicki M and Filipiak M., Microbiological quality of Indoor air in University rooms, Polish. J. of Environ. Stud, 16(2), 623-632 (2007)6.Bush R.K. and Portnoy J.M., The role and abatement of fungal allergens in allergic diseases, Journal of Allergy and Clinical Immunology, 107, 430–440 (2001)7.Bornehag C.G., Blomquist G., Gyntelberg F., Jarvholm B., Malmberg P., Nordvall L. et al., Dampness in buildings and health, (NORDDAMP), Indoor Air,11, 72–86 (2001) 8.Augustowska M. and Dutkiewicz J., Variability of airborne microflora in a hospital ward within aperiod of one year, Ann. Agric. Environ. Med., 13, 99-106 (2006)9.Atlas R. and Bartha R., Ecologia microbiana y microbiologia ambiental, Ed. Pearson Educacion, Madrid (2002)10.Pasquarella C., Pitzurra O. and Savino A., The index of microbial air contamination, J. Hosp. Infect., 46, 241-256 (2000)11.Cheesbrough M., District laboratory practice in Tropical countries, Part 2 Cambridge Low price Editions, 3-8 (2000) 40%24%20%10%6%0%5%10%15%20%25%30%35%40%45%Aspergillus fumigatusAspergillus nigerAlternaria speciesPenicillium speciesRhodotorula species Research Journal of Biological Sciences ___________________________________________________________ ISSN 2278-3202 Vol. 4(9), 48-53, September (2015) Int. Res. J. Biological Sci. International Science Congress Association 53 12.Zafar S., Aqil F and Ahmad I., Metal tolerance and biosorption potential of filamentous fungi isolated from metal contaminated agriculture soil, Bio. resour. Technol, 98, 2557-2561 (2007)13.Mostafa M.A., Al-Fifi Z.I., Alawlaqi M.M. and Al Abboud M.A., Indoor Airborne Fungi in Faculty of Science in Aboarish , Jazan University, Saudi Arabia, Journal of Jazan University, 1(2), 26-35 (2012)14.Shelton B.G., Kimberly H., Kirkland W., Flanders D. and Morris G.K., Profiles of airborne fungi in buildings and outdoor environments in the United States, Applied Environmental Microbiology, 68, 1743–1753 (2002)15.Kavita Naruka and Jyothi Gaur V., Microbial air contamination in a school, In. J. Curr. Microbiol. App. Sci, 2(12), 404-410 (2013)16.Geller R.J., Rubin I.L., Nodvin J.T., Teague W.G. and Frumkin H., Safe and healthy school environments, Pediatr. Clin. North. Am, 54, 351-373 (2007) 17.Jain A.K., Survey of bioaerosol in different indoor working environments in central India, Aerobiologia, 16,221 – 225 (2000)18.World Health Organization: WHO indoor air quality guidelines, Copenhagen: WHO Regional Office for Europe, 1-454 (2010)