Lead Ion Selective Electrode Based on 1, 5-diphenylthiocarbazone
Author Affiliations
- 1 Faculty of Science, Al-azhar University, Cairo, EGYPT
- 2 Hot Labs Center, Atomic Energy Authority, Cairo, EGYPT
Res.J.chem.sci., Volume 2, Issue (6), Pages 38-42, June,18 (2012)
Abstract
PVC based membrane of 1,5-diphenylthiocarbazone (dithizone) reveals a Nernstain potentiometric response with the slope of 29 ± 2 mV per decade for Pb2+ over a wide concentration range (5.0×10-6-1.0×10-2 M). The electrode is suitable for use in aqueous solutions in a pH range of 8 to 10. The response time of the electrode is about 15 s and was used for a period of 45 days. The proposed electrode showed successful applications to the direct determination of lead in a sample of lead water pipe and also as indicator electrode for potentiometric titration of lead ions with NaCl solution.
References
- Abii T.A., Levels of Heavy Metals (Cr, Pb, Cd) Available for Plants within Abandoned Mechanic Workshops in Umuahia Metropolis, Res. J. Chem. Sci., 2(2), 79-82 (2012)
- Eruola A.O., Ufoegbune G.C., Eruola A.O., Awomeso J.A. and Abhulimen S.A., Assessment of Cadmium, Lead and Iron in Hand Dug Wells of Ilaro and Aiyetoro, Ogun State, South-Western Nigeria, Res. J. Chem. Sci., 1(9), 1-5 (2011)
- Garole D.J., Garole V.J. and Dalal D.S., Recovery of Metal Value from Electroplating Sludge, Res. J. Chem. Sci., 2(3), 61-63 (2012)
- Shukur M.M., Kadhim. F.A. and Hassan M.N., Preparation of Alkali Lead Glass and Glass – Ceramic Compositions as Electrical Insulators, Res. J. Chem. Sci., 2(2), 28-34 (2012)
- Barote M.A., Ingale B.D., Tingre G.D., Yadav A.A., Surywanshi R.V. and Masumdar E.U.,Some Studies on Chemically Deposited n-PbSe Thin Films Res. J. Chem. Sci. 1(9), 37-41 (2011)
- Ross J.W. and Frant M.S., Potentiometric Titrations of Sulfate Using an Ion Selective Lead Electrode, Anal. Chem., 41(7), 967-969 (1969)
- Hirata H. and Higashiyama K., Ion Selective Chalcogenide Electrodes for a Number of Cations, Talanta, 19(4), 391-398 (1972)
- Hansen E.H. and Ruzika J., Selectrode the Universal Ion Selective Electrode: Part VIII. The Solid-State Lead(II) Selectrode in Lead(II) Buffers and Potentiometric Titrations, Anal. Chim. Acta, 72(2), 365-373 (1974)
- Grundler P., Behaviour and Analytical Use of Lead Dioxide Electrodes Under Pulse Treatment, Anal. Lett., 14(3), 163-173 (1981)
- Vanstaden J.F., Preparation and Performance of a Coated Tubular Solid-State Lead(II) Selective Electrode in Flow-Injection Analysis, Fresenius Z. Anal. Chem., 333(3), 226-230 (1989)
- Lai S. and Christian G.D., Potentiometric Studies with a Liquid Ion-Exchange Lead-Selective Electrode, Anal. Chim. Acta, 52(1), 41-46 (1970)
- Sharp M., Organic Radical Ion Salts as Selective Electrochemical Sensors, Anal. Chim. Acta, 59(1), 137-142 (1972)
- Srivastava S.K., Gupta V.K. and Jain S., Determination of Lead using a Poly Vinyl Chloride Based Crown Ether Membrane, Analyst, 120(2), 495-498 (1995)
- Tavakkoli N. and Shamsipur M., Lead Selective Membrane Electrode Based on Dibenzopyrydino-18-Crown-6, Anal. Lett., 29(13), 2269-2279 (1996)
- Malinowska E., Brzozka Z., Kasiura K., Egberink R.J.M. and Reinhoudt D.N., Lead Selective Electrodes Based on Thioamide Functionalized Calix [4] arenes as Ionophores, Anal. Chim. Acta., 298(2), 253-258 (1994)
- Sil A., Ijeri V.S. and Srivastava A.K., Coated Wire Silver Ion Selective Electrode Based on Silver Complex of Cyclam, Anal. Sci., 17, 477-479 (2001)
- Watson M. L., Staining of Tissue Sections for Electron Microscopy with Heavy Metals, J. Biophys. and Biochem. Cytol., 4(4), 475–478 (1958)
- Gholivand M.B., Gorji M. and Joshaghani M., Hydrogen Ion Selective Poly Vinyl Chloride Membrane Electrode Based on 2,2'-N,N'-bis(salicylaldimino)azobenzene, J. Iran. Chem. Res., 69-78 (2009)
- Marczenko Z., Spectrophotometric Determination of Elements, John Wiley and Sons Inc., New York (1986)
- Yari A., Shamsipur M., De Filippo G. and Lippolis V., a New PVC Membrane Based Ion Selective Electrode for Perchlorate, Anal. Bioanal. Electrochem., 1(2), 60 – 70 (2009)
- Hassan S., Ali M.M. and Attawiya A., PVC Membrane Based Potentiometric Sensors for Uranium Determination, Talanta, 54, 1153-1161 (2001)
- Ardakani M.M., Zare H.R., Nasirizadeh N. and Safari J., Highly Selective Lead (II) Membrane Electrode Based on New Oxim Phenyl 2- Keto Methyl Quinoline (OPKMQ), Canadian Journal of Analytical Sciences and Spectroscopy, 49(4), 226-233 (2004)